Hi Mona! Can you help me with a load calculation for a residential building in Quezon City?
9:02 AM
Good morning, Juan! 🟢 Of course! I'm switching to Engineer Mode (Electrical, PEC/PESCP jurisdiction) for this.
For a residential building in QC, we'll follow the Philippine Electrical Code (PEC 2017) and apply demand factors per Table 2.20. Let's start:
What info do you have so far?
- Total floor area (m²)
- Number of floors
- Occupancy type (single-family, multi-family, mixed-use?)
- Any specific loads: HVAC, elevator, EV charging?
For a residential building in QC, we'll follow the Philippine Electrical Code (PEC 2017) and apply demand factors per Table 2.20. Let's start:
What info do you have so far?
- Total floor area (m²)
- Number of floors
- Occupancy type (single-family, multi-family, mixed-use?)
- Any specific loads: HVAC, elevator, EV charging?
9:02 AM
It's a 5-storey multi-family residential, 180 sqm per floor, no elevator. Total of 10 units.
9:05 AM
⚙️Engineer Mode — PEC 2017
Load Calculation Summary — PEC 2017
Building: 5F Multi-Family Residential, QC
Gross Area: 900 m² (5 × 180 m²)
Lighting Load:
- 900 m² × 33 VA/m² = 29,700 VA
- Demand factor (10 units, Table 2.20): 43%
- Net lighting: 12,771 VA
Small Appliance Circuits (per unit):
- 2 circuits × 1,500 VA × 10 units = 30,000 VA
- Demand factor: 35% = 10,500 VA
Laundry Circuit (per unit):
- 1,500 VA × 10 units × 100% = 15,000 VA
Estimated Total Demand Load: ≈ 38,271 VA (38.3 kVA)
Recommended service entrance: 60A, 3-phase, 230/400V
This is a preliminary estimate. Final design requires site survey and utility coordination.
Building: 5F Multi-Family Residential, QC
Gross Area: 900 m² (5 × 180 m²)
Lighting Load:
- 900 m² × 33 VA/m² = 29,700 VA
- Demand factor (10 units, Table 2.20): 43%
- Net lighting: 12,771 VA
Small Appliance Circuits (per unit):
- 2 circuits × 1,500 VA × 10 units = 30,000 VA
- Demand factor: 35% = 10,500 VA
Laundry Circuit (per unit):
- 1,500 VA × 10 units × 100% = 15,000 VA
Estimated Total Demand Load: ≈ 38,271 VA (38.3 kVA)
Recommended service entrance: 60A, 3-phase, 230/400V
This is a preliminary estimate. Final design requires site survey and utility coordination.
9:06 AM
Can you generate a formal load schedule document I can submit to Meralco?
9:08 AM
Done! I've generated your Meralco Load Schedule compliant with the Distribution Services and Open Access Rules (DSOAR). The document includes:
- Cover sheet with project details
- Tabulated load schedule per floor
- Demand factor computation table
- Service entrance specifications
- PEC 2017 compliance notes
Saved to your Document Vault. 📄
- Cover sheet with project details
- Tabulated load schedule per floor
- Demand factor computation table
- Service entrance specifications
- PEC 2017 compliance notes
Saved to your Document Vault. 📄
9:09 AM
Salamat! Also remind me to submit this to the building owner by June 10.
9:11 AM
⏰Reminder Set
✅ Reminder set!
📅 June 10, 2026 at 9:00 AM
📌 Submit Load Schedule to building owner (QC Residential project)
📲 Notification via: In-App + WhatsApp
I've also tagged this under your Work/Projects memory so I can follow up proactively. Want me to draft the transmittal letter too?
📅 June 10, 2026 at 9:00 AM
📌 Submit Load Schedule to building owner (QC Residential project)
📲 Notification via: In-App + WhatsApp
I've also tagged this under your Work/Projects memory so I can follow up proactively. Want me to draft the transmittal letter too?
9:11 AM
Yes please! And make it formal, Engr. Santos is the building owner.
9:13 AM
You
Yes please! And make it formal...
TRANSMITTAL LETTER
June 10, 2026
Engr. Maria Santos
Building Owner
Quezon City, Metro Manila
Dear Engr. Santos,
Please find attached the Electrical Load Schedule for the proposed 5-storey multi-family residential building located in Quezon City, prepared in accordance with the Philippine Electrical Code (PEC 2017) and Meralco DSOAR requirements.
The document contains the complete load computation, demand factor analysis, and service entrance specifications for your reference and submission to Meralco Distribution.
Should you have any questions or require revisions, please do not hesitate to contact the undersigned.
Respectfully,
Juan Dela Cruz, REE
Registered Electrical Engineer
PRC License No. XXXX-XXXXX
June 10, 2026
Engr. Maria Santos
Building Owner
Quezon City, Metro Manila
Dear Engr. Santos,
Please find attached the Electrical Load Schedule for the proposed 5-storey multi-family residential building located in Quezon City, prepared in accordance with the Philippine Electrical Code (PEC 2017) and Meralco DSOAR requirements.
The document contains the complete load computation, demand factor analysis, and service entrance specifications for your reference and submission to Meralco Distribution.
Should you have any questions or require revisions, please do not hesitate to contact the undersigned.
Respectfully,
Juan Dela Cruz, REE
Registered Electrical Engineer
PRC License No. XXXX-XXXXX
9:14 AM
Perfect! Save that to my documents too.
9:15 AM
Saved! 📁 "Transmittal_Letter_Santos_Jun10.docx" added to your Document Vault under Professional > Engineering.
Anything else I can help with for this project? I can also:
- Generate the single-line diagram
- Compute panel board schedules
- Estimate material quantities
Anything else I can help with for this project? I can also:
- Generate the single-line diagram
- Compute panel board schedules
- Estimate material quantities
9:15 AM
⚙️Engineer Quick Actions
⚙️Engineer Mode active — ask anything related to engineer work